Overriding the default time to execute an ARM report

$
0
0

THE INFORMATION IN THIS ARTICLE APPLIES TO:

  • EFT Server Enterprise version 6.2.22 and 6.3

DISCUSSION

The number of seconds that are allowed for an ARM report to execute can be changed from the 60-second default. This value is only read from the registry once, so a restart is required to change the value.

  • If the ARM report is being run from within the Reports tab, then the EFT Server administration interface is running the report and only the interface needs to be restarted.
  • If the ARM report is being run from an Event Rule Action, then the EFT Server service must be restarted to change this value.

32-bit:

[HKEY_LOCAL_MACHINE\SOFTWARE\GlobalSCAPE Inc.\EFT Server 4.0\

64-bit:

[HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\GlobalSCAPE Inc.\EFT Server 4.0\

Create DWORD DBTimeout and specify the number of seconds for the ARM report to complete.